公司产品
HYDRA-CELL G-12
G12 Series (Metric)
G12 - Flow Capacities @ 69 Bar (1000 Psi) 4-Pole Motor @ 50 Hz | ||||||
Model | rpm | gpm | l/min | |||
G10-E | 1450 | 6.63 | 25.1 | |||
G10-I | 1450 | 3.30 | 12.5 | |||
G10-S | 1450 | 4.96 | 18.8 | |||
G10-X | 1450 | 8.10 | 30.6 | |||
G12 - Flow Capacities @ 69 Bar (1000 Psi) 6-Pole Motor @ 50 Hz | ||||||
Model | rpm | gpm | l/min | |||
G10-E | 960 | 4.39 | 16.6 | |||
G10-I | 960 | 2.19 | 8.3 | |||
G10-S | 960 | 3.28 | 12.4 | |||
G10-X | 960 | 5.19 | 19.6 | |||
G12 - Delivery @ 69 Bar (1000 Psi) | ||||||
Model | gal/rev | liters/rev | ||||
G10-E | 0.0051 | 0.0191 | ||||
G10-I | 0.0023 | 0.0086 | ||||
G10-S | 0.0034 | 0.0130 | ||||
G10-X | 0.0056 | 0.0211 | ||||
G12 - Other Specifications | ||||||
Maximum Discharge Pressure | ||||||
Metallic Heads: | 69 bar (1000 psi) | |||||
Maximum Inlet Pressure | 17 bar (250 psi) | |||||
Maximum Operating Temperature | ||||||
Metallic Heads: | 121 ̊C (250 ̊F) - Consult factory for correct component selection for temperatures from 71 ̊C (160 ̊F) to 121 ̊C (250 ̊F). | |||||
Maximum Solids Size | 500 microns | |||||
Inlet Port | 1 inch BSPT | |||||
1 inch NPT | ||||||
Discharge Port | 3/4 inch BSPT | |||||
3/4 inch NPT | ||||||
600lb ANSI RF flange | ||||||
Shaft Diameter | 22.2 mm (7/8 inch) | |||||
Shaft Rotation | Reverse (bi-directional) | |||||
Bearings | Tapered roller bearings | |||||
Oil Capacity | 1.4 liters (1.5 US quarts) | |||||
Weight | ||||||
Metallic Heads: | 28.6 kg (63 lbs.) | |||||